VDMA 24020-1:2008-11 “Operational Requirements for Refrigerating Systems”

13.03.2017 VDMA 24020-1 supports operators in fulfilling operator obligations and provides recommendations for the safe operation of ammonia refrigeration systems. Notes are as well given for old systems in particular.

Show article

VDMA 24020-2:2008-11 “Operational Requirements for Refrigerating Systems”

04.12.2015 “Operational Requirements for Refrigerating Systems” provides recommendations for the safe operation of refrigeration systems. Part 2 covers non flammable refrigerants, which are in the safety group A1 according to EN 378-1.

Show article

VDMA 24243:2005-08 “Refrigerating Machines and Systems, Leak Tightness of Refrigerating Systems and Heat Pumps Leak Detection / Leak Testing

24.11.2015 For proper leak testing, it is necessary to formulate leak-tightness requirements for refrigeration systems which means defining expertise and permissible types of leakage.

Show article

Energy efficiency of refrigeration systems, Part 5: Industrial refrigeration

03.04.2019 VDMA 24247-5 "Energy Efficiency of Refrigeration Systems, Part 5: Industrial Refrigeration" provides planners and operators with information on how and by what means the energy efficiency of refrigeration systems and cooling processes in industry can be optimised and how the operator can exert influence by complying with maintenance requirements.

Show article

VDMA 24247-1:2011-11 “Energy Efficiency of Refrigerating Systems”

13.03.2017 VDMA 24247-1 "Contribution of refrigerating and air conditioning systems to climate protection – Improvement of energy efficiency – Reducing greenhouse-related emissions”. The VDMA Specification describes measures to achieve the energy savings potential up to 40%.

Show article

VDMA 11499:2008-08 “Operation and use of refrigerated display cabinets”

13.03.2017 The VDMA Refrigeration and Heat Pump Technology Association has published VDMA Specification 11499:2008-08 “Operation and use of refrigerated display cabinets” in collaboration with the Fachgruppe Kühlmöbel (Specialized Group Refrigeration Cabinets), and the Fraunhofer Institute for Process Engineering and Packaging.

Show article

VDMA 11498:2011-04 “Operating costs of refrigerated display cabinets”

13.03.2017 VDMA 11498:2011-04 “Operating costs of refrigerated display cabinets” provides planning assistance for the layout design and for incorporating refrigerated display cabinets into the overall concept of food stores. The VDMA Specification helps in deciding on the right type of device and the use of different equipment options for cost-optimized operation.

Show article

Dr. Karin Jahn

Technical Manager of sector department Refrigeration and Heat Pump Technology, Managing Director Research Council for Refrigeration technology, Managing Director eurammon, Specialized Group Refrigerated Cabinets

Phone: 

(+49 69) 66 03-12 77


Fax: 

(+49 69) 66 03-22 77


karin.jahn@vdma.org

Cornelia Roth

Assistant Refrigeration and Heat Pump Technology, eurammon, Research Concil for Refrigeration Technology and Specialized Group Refrigerated Cabinets

Phone: 

(+49 69) 66 03-12 76


Fax: 

(+49 69) 66 03-22 76


cornelia.roth@vdma.org